Model 354

SKU: 354

Pump Controller, Four Relay, 4-20mA

The Delta Controls Model 354 is designed to be operated as an alarm unit and/or adjustable differential level controller. It has two relays with each relay featuring an individual 0% to 100% On and 0% to 100% Off setpoint. It accepts a 4-20 mA dc input signal which is proportional to some process variable–usually level. The Model 354 is microprocessor based and checks its input signal loop for integrity. The relays may be set up for Direct or Reverse fail-safe action.

The 354 is equipped with a built-in loop power supply and it can accept a remotely powered 4-20 mA dc signal. The input signal wiring may be equipped with an electrical barrier. The 354 must be located in a ‘safe’ area. The input signal wires may extend into the ignition hazard area.

The 354 may be operated in the pump controller mode. Features, such as lead/lag pump rotation, time delay starting, and alarms may be programmed in the field. Up to two pumps can be controlled and/or two alarm points can be actuated from a single module.

Features

  • Microprocessor based
  • Available for mounting in Delta Controls housings or in enclosures by others
  • Housings may be surface or pipe stand mounted
  • Optional direct reading LCD display
  • Accepts 4-20 mA dc signal from any type transmitter; 2, 3 or 4-wire
  • Supplies DC power for 2-wire loops, and for 3 or 4-wire transmitters
  • Field selectable fail-safe action
  • Optional pump control functions
  • Lead/lag control
  • Relay operate time delays
  • Two alarm points
  • Built-in loop power supply
  • Selectable starting time delay
  • Self-checking diagnostic routine
  • Will not lose memory
  • Continuous setpoint indication
  • Optional explosion-proof housing

Specifications

  • General Type: Microprocessor based
  • Supply Power: 120 ACV or 240 ACV 50 Hz or 60 Hz or DCV ± 15% variation
  • Input Range: 4-20 mA dc
  • Relays 4,10 A @ 250 ACV SPDT
  • Basic Switching Action: Adjustable differential for On/Off control may be selected
  • Accuracy: 0.1% of full scale
  • Transmitter Loop Power Supply: 24 DCV
  • Multiple Pump Control: Selectable lead/lag; rotation of up to 4 pumps
  • Readout Display (Optional): 3.5 digit LCD May be field calibrated to be direct reading in engineering units
  • Temperature Range: -20 °F to +170 °F (-20 °C to +77 °C)
  • Signal Loop (Optional Barrier): Signal Loop (Optional Barrier):

Required Ordering Information

  • Detailed model number
  • Tag or nameplate detail (if required)
  • Documentation/testing tiers (if required, refer to Additional Resources in the product catalog)

Additional Information

Subheader

Pump Controller, Four Relay, 4-20mA

Level Measurement

Point, Pump Controllers

Accessories and Related Products