Delta Controls Home

MODEL P71 FLEXIBLE CABLE PROBE

FOR USE WITH CONDUCTIVE LIQUIDS

Download the Delta Controls Model P71 Detailed Datasheet 
Note: You will need the Acrobat Reader to view the data sheet. 


Features
· Cable can be coiled for easy handling and shipment
· Easily installed in tall tanks
· Can be installed in indoor tanks with low headroom
· PTFE Teflon® insulation allows operation in conductive or nonconductive liquids at high temperatures
· Corrosion resistant PTFE Teflon® seals and jacket
· Suitable for high pressures and temperatures
· Available in 316 S.S. or Hastelloy® "C"

Application
The Delta Controls Model P71 probe cable is jacketed with PTFE Teflon® insulating material and the bottom cable fitting is electrically isolated from the cable. The probe should normally be located near and not more than 1/4 of the vessel diameter away from the vessel centerline. The P71 is primarily intended for liquid and interface measurement service. However there are some other applications that require its attributes. These include damp wood chips and pulpstock chests.

The cable is provided with a bolt thread for direct attachment to the bottom of the tank. It may also be equipped with a lower weight to keep it straight. The cable must be vertical and taut after installation. A simple bottom weight is the preferred method in calm, still storage tanks. A pipe stilling well should be used in conjunction with the weight when the liquid is agitated or where strong flowing currents are present.

Fastening the lower cable termination to the bottom of an agitated tank is required when a stilling well cannot be installed or in applications where the stilling well may plug with deposits. This method has a significant disadvantage because the tank must be drained for either installation or removal of the cable probe.

Specifications
Working Pressure: 1500 PSIG (100 BAR) at 100°F (40°C)
Working Temperature: -460 to +400°F (-273 to +200°C)
Temperature Extension: Required for less than -20°F (-30°C) or higher than 175°F (80°C)
Insertion Length:
Up to 250 feet (75 meters)
Process Connection:
MPT is basic, flanged (any type) is optional
Electronic Module: Compatible with all Delta Controls Models
Wall Mount Support Bracket: Optional


Go to Delta Controls Home Page