Delta Controls Home Page

SERIES 700

MAXIMUM RELIABILITY MECHANICAL LEVEL SWITCHES

Download the Delta Controls Series 700 Summary Datasheet 
Note: You will need the Acrobat Reader to view the data sheet.


SUMMARY OF MODELS AND STYLES

TOP INSERTED FLOAT ACTUATED LEVEL SWITCHES

Operation: A float is carried up and down by variations in liquid level or interface position.
                     One or more switch actions occur at selected level positions.

Model
709

 

Delta Controls Model 709 Alarm

  • Uses: Provide high or low level alarm or interface position
  • Insertion: Up to 10 feet (3m) below the flange face
  • Switch Action: Single point
  • Specific Gravity: From 0.35 to 2.40 SGU
  • Temperature: From –150 to 750°F (-100 to +400° C)
  • Pressure: From –15 to 1200 PSIG (-1 to +80 BAR)
  • Process Connection: 1" to 4" NPT threaded; 1" to 12" flanged, up to 900# rating; ASA, DIN or JIS equivalent

Model
710

Model
711

 

709.jpg (7661 bytes)

 

Delta Controls Multiswitch Models 710 and 711

  • Uses: Provide high and / or low level alarm, pump control, etc.
  • Insertion: Up to 10 feet below the flange face
  • Switch Action: From 1 to 4 points of alarm and/or differential; up to 60" differential available with Type 711
  • Specific Gravity: From 0.35 to 2.40 SGU
  • Temperature: From –150 to 750°F (-100 to +400° C)
  • Pressure: From –15 to 1200 PSIG (-1 to +80 BAR)
  • Process Connection: 1" to 4" NPT threaded; 1" to 12" flanged, up to 900# rating; ASA, DIN or JIS equivalents

TOP INSERTED DISPLACER ACTUATED LEVEL SWITCHES

Operation: The weight of a displacer is supported by a spring. Variations in liquid level cause the displacer to move up and down. Switching action occurs as the level passes each displacer.

Model
715

 

Delta Controls Model 715 Alarm

  • Uses: High or low alarm for liquid level or interface position
  • Insertion and Switching band: up to 50 feet (15m) maximum
  • Switch action: Single point alarm
  • Specific Gravity: form 0.25 to 2.4 SGU
  • Temperature from –20 to 500°F (-30 to +260° C)
  • Pressure: from –15 to 2200 PSIG (-1 to +155 BAR)
  • Process Connection: 2" to 4" NPT threaded; 2" to 12" flanged up to 1500# rating; ASA, DIN, or JIS equivalents

Model
716

Model
717

Model
718

 

Delta Controls Model 716, 717, 718 Multiswitch

  • Uses: High and/or low alarm; single and multiple pump control
  • Insertion and Switching band: up to 50 feet (16 m) maximum
  • Switch action: From 1 to 4 points of alarm and/or on-off pump control
  • Specific Gravity: form 0.25 to 2.4 SGU
  • Temperature from –20 to 500°F (-30 to +260° C)
  • Pressure: from –15 to 2200 PSIG (-1 to +155 BAR)
  • Process Connection: 3" to 4" NPT threaded; 3" to 12" flanged up to 1500# rating; ASA, DIN, or JIS style

SIDE INSERTED FLOAT OR DISPLACER ACTUATED LEVEL SWITCHES

Operation: A solid displacer or heavy-duty float is supported by a pivot shaft and counterweight. Single point alarm switching action occurs as the liquid level or interface position crosses the center line of the body.
Uses: High and low alarm for level, interface position, and sequencing

Model
735

 

Delta Controls Model 735 Alarm
NPT Process Connection

  • Insertion: 14 inches basic
  • Specific Gravity: 0.6 to 2.4
  • Temperature: -85 to 1000°F (-60 to +540° C)
  • Pressure: –15 to 2250 PSIG (-1 to +155 BAR)
  • Process Connection:1" to 3" threaded, 1 ½" to 4" flanged, up to 900# rating, ASA, DIN, JIS
Model
735

 

Delta Controls Model 735 Alarm
Flanged Process Connection

  • Insertion: 12 to 24 inches
  • Specific Gravity: 0.15 to 2.4
  • Temperature: -85 to 1000°F (-60 to +540° C)
  • Pressure: –15 to 3600 PSIG (-1 to +250 BAR)
  • Process Connection: 2" to 12" flanged, up to 1500# rating, ASA, DIN, JIS, any facing
Model
740

 

Delta Controls Model 740 Two Point Alarm or Differential Pump Control

  • Operation: A pivoted float rides on the liquid level or interface position. Two switch actions occur as the elevation varies.
  • Uses: Two point alarm or on-off pump control
  • Specific Gravity: 0.4 to 2.4
  • Temperature: -50 to 750°F (-47 to +400° C)
  • Pressure: -15 to 750 PSIG (-1 to +50 BAR)
  • Process Connection: 3" NPT threaded, 3" to 12" flanged, up to 600# rating, ASA, DIN, JIS

EXTERNAL CAGE FLOAT OR DISPLACER ACTUATED LEVEL SWITCHES
Model
750

 

Delta Controls Model 750 Float or Displacer
Level or Interface Alarm

  • Operation: The weight of a displacer or heavy-duty float is supported by a counterweight and a pivot shaft. Switching occurs as the level (interface) crosses the body centerline.
  • Specific Gravity: 0.23 to 2.4
  • Temperature: -200 to 1100°F (-130 to +650° C)
  • Pressure: –15 to 6000 PSIG (-1 to +410 BAR)
  • Process Connection: Top/Bottom or other
    ½", ¾", or 1" NPT or Socket Weld
    ½" to 2" flanged, 600#, ANSI
    ½" to 1" flanged, 1500#, ANSI
    ½" to 2" hubs, 10,000#, Greyloc

Model
760

Model
762

762.jpg (12169 bytes)

Download the Series 762 Detailed Datasheet 

 

Delta Controls Model 760 and 762 Alarm with Vertically Rising Element

  • Operation: A float or displacer moves up and down as the liquid level (interface) varies. Switch action occurs at a preset elevation
  • Switching: Single alarm
  • Specific Gravity: 0.35 to 2.4
  • Temperature: -100 to 800°F (-70 to +430° C)
  • Pressure: –15 to 20,000 PSIG (-1 to 1400 BAR)
  • Process Connection:
    SB or SSB style
    ½", ¾", or 1" NPT, stub, or S. W.
    ½" to 2" flanged, to 2500#, ANSI
    2" Greyloc clamp hubs

Model
765

Model
767

Model
770

 

Delta Controls Model 765, 767, and 770
Differential Control or Multiswitch

  • Operation: A float with a long stroke action moves up and down as the liquid level varies. Switching occurs at up to four separate points.
  • Switching Stations: 1 to 4; alarm and/or differential
  • Differential: up to 72"
  • Specific Gravity: 0.4 to 2.4
  • Temperature: -20 to 750°F (-30 to +400° C)
  • Pressure: -15 to 2200 PSIG (-1 to +155 BAR)
  • Process Connection: Same as type 760

HIGH TEMPERATURE AND PRESSURE LEVEL SWITCH
Model 763
763.jpg (9637 bytes)

 

Delta Controls Model 763 With Displacer Element

  • Operation: A counterweighted horizontal pivoting element operates an output switch as the liquid level or interface crosses the body centerline.
  • Uses: Steam drums, condensate trap drains, Dowtherm®, etc.
  • Switch Action: Single point alarm
  • Specific Gravity: 0.3 to 2.4 units
  • Interface Differential: 0.1 unit minimum
  • Temperature: -350 to 1100°F (-200 to +600° C)
  • Pressure: -15 to 6000 PSIG (-1 to +415 BAR)
  • Process Connection: 1", 1 ½", or 2" butt, stub, or socket weld; ANSI flanges or Greyloc hub
Third Party Approvals
CSA (Canada)
NRTL (USA)
ISO-9001 Quality System

Application Note
Condensate Level Switches for Steam Service

Data Sheets
By Model Number

Contact Delta Controls

 
Go to Delta Controls Home Page
Delta Controls Home Page