MODEL
572
SANITARY
PRESSURE/LEVEL TRANSMITTER
WITH MODULAR ELECTRONICS
Download the
Delta Controls Model 572 Detailed Datasheet
Note: You will need the Acrobat Reader to view the data sheet.
Features
- Two wire loop powered
4-20 mADC signal
- Fits Ladish, APC, and
other sanitary connections
- Suitable for
ultraclean water service
- Suitable for CIP/SIP
service
- Removable electronic
module
- Polished body is basic,
polished housing optional
- Zero & span pots
for field recalibration
- Spark & power surge
protection
- Optional dampening
- Optional LCD display
- Maintenance free operation
Typical
Applications
Ultraclean water, fruit
Juice, fermentation tanks, vegetable oil, milk processing, beer, wine, spirits,
candy making, pharmaceutical reactors.
Description
The Delta
Controls Model 572 Level and Pressure Transmitter was designed specifically
for food, pharmaceutical and ultraclean applications. The 572 consists of a
potted electronic module in a housing which is mounted with a modular pressure
sensor as a packaged assembly. The wetted sensor is constructed of 316 S.S.
The body is polished and free from crevices, cracks, and voids that can harbor
contaminants. The back of the sensor is usually vented to atmosphere to compensate
for barometric pressure changes.
Cleaning of the Delta Controls
Model 572 can easily be accomplished by disassembly and manual washing, or it
can be cleaned and sterilized in place. The Model 572 can also be used as a
liquid level transmitter in vented tanks. The pressure at the bottom of a vented
tank containing liquid is linearly proportional to the height and density of
the liquid. Use the TPC Corrector to compensate for the gas space pressure when
the tank is pressurized.
Specifications
- Technology:
Silicon strain gage
- Supply Power:
13 to 35 VDC 2 wire loop powered
- Output Signal:
4-20 mADC, isolated, intrinsically safe
- Loop Impedance:
550 ohms at 24 VDC,1100 ohms at 35 VDC
- Adjustments:
Span from 30% to 100% of range, zero to 30% is basic, non-interactive.
- Over Pressure:
2X Range, 35 PSI (2.5 Bar) minimum without damage; 3X Range 1000 PSI (70 Bar)
minimum without rupture
- Temperature
Range:
- -20 to +220°F (-30
to 105°C) Process
- -20 to +185°F (-30
to +85°C) Electronics
- 30 to +130°F (-1
to +55°C) Compensated (Higher Available)
- Accuracy:
± 0.25% F.S. or better
- Thermal Error:
± 0.02% F.S. / °F maximum
- Barometric Effect:
None
Optional
Features
- Dampening: Selectable
0.1 to 22 seconds
- Indicator: Large direct
reading LCD
- Alarm Points: 1 or 2,
5 Amp SPDT Contacts
- Power Supply: Integral
VAC to 24 VDC
- TPC Corrector: Level
measurement in unvented and pressurized tanks. (Use for gas space compensation
in pressurized tanks)
Third Party
Approvals
- CSA (Canada)
- NRTL/C (USA)
- Intrinsically safe
- Explosion proof
- Environment proof
- 3A Sanitary (Worldwide)
- ISO-9001 Quality System
Go to Delta
Controls Home Page
Go to Delta
Controls Pressure Transmitter Page