Features
- Two Wire Loop Powered
4-20 mADC Signal
- Suitable For Dirty Liquids
And Slurries
- Integral Or Remoted,
Potted Electronic Module
- Oil Filled Sensor Isolating
Diaphragm
- Transmission of Liquid
Temperature Over A Second 2-Wire 4-20 mA Loop
- Ranges From 12 Inches
To 36 Feet (0.3 to 11 M) water column
- Zero & Span Pots
For Field Calibration
- Optional LCD Display
And Alarm
- Optional 20-4 mADC Reverse
Calibration
- Optional Isolation Bladder
For Vent Tube
- Technology Used Does
Not Require A Ground Reference Rod When The Container Is Nonconductive
- Not Affected By Product
Coating Or Algae Buildup
- Maintenance Free Operation
Description
The Delta
Controls Model 562 level transmitter consists of a potted electronic
module and a pressure sensing probe. The probe consists of a cable connected
sensor supported and protected by a S.S. body and supported by a rigid 3/4"
Sch 40 pipe. The electronics housing can be mounted directly on the probe head
or remotely for convenience or safety. The length of supporting pipe can be
supplied by Delta Controls or by the user.
Typical
Applications
When the Delta Controls
Model 562 is installed in a tank, sump, basin or other containment, the strain
gage sensor detects the pressure exerted on it by the water or other liquid
surrounding it. This pressure is linearly proportional to the height and density
of the liquid above the sensor. There are no cavities and the diaphragm is completely
open to the liquid being measured. The sensor cannot be plugged and rendered
inoperable by liquids with high solids contents. Waste liquids and slurries
are easily handled.
The top mounting feature
of the Model 562 makes it easy to use in concrete basins, sumps and other containments
where bottom or side mounting of a sensor would be difficult or impossible.
Compared to a capacitance probe transmitter, it requires neither reference ground
nor periodic cleaning and recalibration to function accurately and reliably.
The 562's probe can be mounted
using a wide range of NPT and flanged connections. It can also be supplied with
either a vertical wall or a horizontal ledge mounting bracket for support over
basins, open tanks, pits, and similar installations. The sensor is referenced
to atmospheric pressure through a vent tube. A desiccant filter or isolation
bladder prevents moisture condensation in the tube.
Specifications
- Technology:
Silicon strain gage
- Output:
4-20 mADC Isolated; Intrinsically Safe
- Supply Power:
13 to 35 VDC 2 Wire loop powered
- Loop Impedance:
550 ohms at 24 VDC. 1100 ohms at 35 VDC
- Adjustments:
Span from 30% to 100% of sensor range and Zero to 30% suppression is basic,
non-interactive.
- Protective Devices:
Transient suppressers for voltage surge and spark protection.
- Cable Jacket:
PVC basic; TEF optional
- Temperature
Range:
- -20 to +220°F (-30
to 105°C) Process
- -20 to +185°F (-30
to +85°C) Electronics
- 30 to +130°F (-1
to +55°C) Compensated (Higher Available)
- Accuracy:
± 0.25% F.S. or better
- Thermal Error:
± 0.02% F.S./ °F maximum
- Over Pressure:
2X Range (35 PSI / 2.5 Bar min) without damage ; 3X Range, 1000 PSI (70 Bar)
minimum without rupture
- Barometric Effect:
None (Note: Use The "TPC" Corrector to correct for gas space pressure
in unvented and pressurized tanks.)
Optional
Features
- Dampening:
Selectable, 0.1 to 22 seconds.
- Condensation
Protection: Desiccant chamber or Isolation Bladder on vent tube.
- Indicator:
Large LCD display in engineering units.
- DC Power Supply*:
VAC to 24 VDC output.
- Alarm Module*:
Integral 5 amp, SPDT; 1 or 2. (Not third party listed)
- Liquid Temperature
Option: A separate 2-wire 4-20 mADC loop transmitter can be included
in the Model 562 housing. A precision temperature sensor is mounted with the
level sensor. Range: Can be any from 50 to 250°F (30 to 140°C) span between
-50 and +250°F (or corresponding span in metric units). Accuracy is &plusm; 0.5°F.